1. Registration trouble? Please use the "Contact Us" link at the bottom right corner of the page and your issue will be resolved.
    Dismiss Notice

Cooling question.

Discussion in 'Builds and Fabricators Forum' started by GreenGhost, Sep 16, 2013.

  1. Sep 25, 2013
    GreenGhost

    GreenGhost Never give up!

    Linglestown, PA
    Joined:
    Apr 6, 2008
    Messages:
    291
    Third times a charm! The final product
    [​IMG]

    with a fan that moves air the right direction. :rofl:

    now time to work on wiring it in.
     
  2. Sep 26, 2013
    tomatolane

    tomatolane Lane

    Chattanooga...
    Joined:
    Sep 3, 2012
    Messages:
    465
    Just A ?.

    Could you have not just reversed the wires on your old fan?
    Most electric fans actually will rotate each way with a wire reversal.
     
  3. Sep 26, 2013
    GreenGhost

    GreenGhost Never give up!

    Linglestown, PA
    Joined:
    Apr 6, 2008
    Messages:
    291
    It had directional blades, They were meant to push air. When I tried reversing the wires it didn't work well, it would rotate backwards but the air flow was really poor.
     
    Last edited: Sep 26, 2013
  4. Sep 27, 2013
    jpflat2a

    jpflat2a what's that noise?

    Hermosa, SD
    Joined:
    Jul 30, 2003
    Messages:
    8,526
    Not fan related...
    I'd take the radiator out and have the large cap radiator neck (4/6 lb cap) replaced with the smaller, more modern neck.
    Then you can run a modern 14/16 pound radiator cap. Higher pressure will help.
    The radiator will hold up just fine.....for the naysayers out there.
    It's what I did, it works, and it's my opinion.
     
  5. Sep 30, 2013
    Warloch

    Warloch Did you say Flattie??? Staff Member

    Falcon, CO
    Joined:
    Mar 4, 2003
    Messages:
    5,477
    FWIW - I have the same on one rig, with the org on another.
     