1. Registration trouble? Please use the "Contact Us" link at the bottom right corner of the page and your issue will be resolved.
    Dismiss Notice

MSD igniton points prob

Discussion in 'Early CJ5 and CJ6 Tech' started by Hippo393, Mar 24, 2006.

  1. Mar 24, 2006
    Hippo393

    Hippo393 Jeepless

    Charlotte, NC
    Joined:
    Sep 22, 2002
    Messages:
    1,130
    Just installed MSD 5 for the '5. :) I like it! One problem though....it seems to confuzzle the dwell meter. Is this a likely side affect? According to the meter my optimal dwell is at ~46*. :? Am I going to have to uninstall the unit and reinstall to stock just to check/set my dwell to 29-30*? :?
     
  2. Mar 24, 2006
    Mcruff

    Mcruff Earlycj5 Machinist

    Albertville, AL
    Joined:
    Sep 22, 2002
    Messages:
    5,349
    Dwell is no longer controlled by the points, it is controlled by the MSD, so long as the points are set to open at least as wide as the original setting they are now only a trigger unit and not the unit that sets the dwell.
     
  3. Mar 24, 2006
    Hippo393

    Hippo393 Jeepless

    Charlotte, NC
    Joined:
    Sep 22, 2002
    Messages:
    1,130
    Oh, ok. :?
    :D
    So how do you set the dwell then? I had to fudge it trial & error with an allen wrench thru that Delco cap window. You could use a feeler gauge to measure the distance from my knuckles to the fan-of-death in the process. So how then?
     
  4. Mar 24, 2006
    sparky

    sparky Sandgroper Staff Member Founder

    Perth, WA
    Joined:
    Sep 20, 2002
    Messages:
    9,221
    You don't, the MSD sets it. Set the gap to the proper gap and leave it.
     
  5. Mar 24, 2006
    termin8ed

    termin8ed I didn't do it Staff Member

    Mason, MI
    Joined:
    Dec 22, 2002
    Messages:
    4,422
    Set the gap when the engine is OFF! :D
    don't need it to be running when you set the gap.
     