1. Registration trouble? Please use the "Contact Us" link at the bottom right corner of the page and your issue will be resolved.
    Dismiss Notice

hard starting

Discussion in 'Intermediate CJ-5/6/7/8' started by walterv, Feb 11, 2006.

  1. Feb 11, 2006
    walterv

    walterv Member

    Yakima Wa.
    Joined:
    Sep 1, 2004
    Messages:
    201
    Well, got a 75 304 with a mallory coil and distributor. The motor will fire right up run a few seconds and die. It will crank several times with no fire from the coil, let it set a few minutes and it will fire up again. It will do this 3 or 4 times then will start and run. It will start and run fine until it sets all day at work or all night at home. Is there something that needs replaced? I did replace the ign, and checked all the wiring. Thanks for any ideas/help. Walt
     
  2. Feb 11, 2006
    walterv

    walterv Member

    Yakima Wa.
    Joined:
    Sep 1, 2004
    Messages:
    201
    Just FYI, seems the problem is the porcelin ballast resistor. When the motor cranks with no fire, I can use a jumper wire to bypass the resistor and it will start and stay running. Take the jumper wire off and it will crank with no fire.
     
  3. Feb 11, 2006
    Patrick

    Patrick Super Moderator Staff Member

    Los Alamos, NM
    Joined:
    Sep 22, 2002
    Messages:
    8,360
    Did you check the voltage on the + side of the coil? Should be ~12 or so while cranking, and drop to something around 9 while running. Sounds like the ballast may be junk...
     
  4. Feb 12, 2006
    walterv

    walterv Member

    Yakima Wa.
    Joined:
    Sep 1, 2004
    Messages:
    201
    That was the problem. The ballast is junk.
     