1. Registration trouble? Please use the "Contact Us" link at the bottom right corner of the page and your issue will be resolved.
    Dismiss Notice

Alternator not charging, maybe voltage regulator need help

Discussion in 'Intermediate CJ-5/6/7/8' started by scbasspro, Oct 2, 2011.

  1. Oct 2, 2011
    scbasspro

    scbasspro Big Ed

    Chapin SC
    Joined:
    Nov 2, 2007
    Messages:
    63
    OK, Alternator not charging. Replaced alternater and still not charging. Looking at charging system I have two electrical boxes. One larger rectanglar box and a smaller box also mounted to the wheel well. Not sure which is voltage reg. I have a 1976 CJ 304 with a replacement wire harness. Any help would be appreciated.
     
  2. Oct 2, 2011
    timgr

    timgr We stand on the shoulders of giants. 2022 Sponsor

    Medford Mass USA
    Joined:
    Aug 10, 2003
    Messages:
    23,596
    If you have the original ignition system, the larger box is the ignition module and the smaller box is the voltage regulator. Here's a picture of the module:

    [​IMG]

    Check the manual - lots of good info there. http://oljeep.com/gw/76_tsm/Section3.pdf

    A '76 has a Motocraft alternator, which is inferior to the Delco used with sixes that year. Jeep switched to only the Delco alternator a few years later. I would not replace a Motorcraft with a Motorcraft - especially since you have a replacement harness, and the Delco alternator has an internal regulator - so you replace both if you upgrade.
     
  3. Oct 2, 2011
    scbasspro

    scbasspro Big Ed

    Chapin SC
    Joined:
    Nov 2, 2007
    Messages:
    63
    Thanks, I recognize the module. I have the alternater that requires external voltage regulator. Do you have a schematic of the voltage reg wiring? I notice one of the wire connectors have a missing wire. Thanks again!!!!!!!!!!!!!!!!!!
     
  4. Oct 3, 2011
    Walt Couch

    Walt Couch sidehill Cordele, Ga. 2024 Sponsor 2023 Sponsor 2022 Sponsor

    cordele, Ga.
    Joined:
    Mar 29, 2007
    Messages:
    5,925
    Look at page 3-11 and 3-12 of the pdf file that Tim shows and you will see the "I" (ignition) terminal on the regulator is not used.
     
  5. Oct 3, 2011
    scbasspro

    scbasspro Big Ed

    Chapin SC
    Joined:
    Nov 2, 2007
    Messages:
    63
    I got it, new voltage reg did the job, Thanks
     