1. Registration trouble? Please use the "Contact Us" link at the bottom right corner of the page and your issue will be resolved.
    Dismiss Notice

electrical problems

Discussion in 'Early CJ5 and CJ6 Tech' started by 66cj5, Jul 11, 2005.

  1. Jul 11, 2005
    66cj5

    66cj5 Jeep with no name

    NorthWest Indiana
    Joined:
    Sep 10, 2003
    Messages:
    2,084
    just got done installing the electric fan and now I have no power @ the iginition switch. I have 12.9 volts @ the battery, winch solinoid and battery. the jeep shut off on it's own while I was adjusting the temp switch. any thoughts/ideas??????
     
  2. Jul 14, 2005
    Roboter

    Roboter Klaatu Barada Jeepto

    Loomis California
    Joined:
    Apr 13, 2005
    Messages:
    316
    Blown fuse :?
     
  3. Jul 16, 2005
    66cj5

    66cj5 Jeep with no name

    NorthWest Indiana
    Joined:
    Sep 10, 2003
    Messages:
    2,084
    checked fuses. thinking fuseable link or ign switch. (or the hacked rats nest wiring under dash [again])
     
  4. Jul 17, 2005
    66cj5

    66cj5 Jeep with no name

    NorthWest Indiana
    Joined:
    Sep 10, 2003
    Messages:
    2,084
    found the problem (I think) seems that the hacked wire job has the hot wire from the alt going to the headlight switch then the ign switch. seems the headlight switch is bad and since i have no lights (yet), am going to bypass headlight switch.
     
  5. Jul 17, 2005
    kamel

    kamel Senior Curmudgeon

    Erlanger, Kentucky
    Joined:
    Jun 10, 2003
    Messages:
    891
    Whoa!!!

    wire from battery to light switch is normal. It isn't the only way to connect it, but it is not 'wrong' or indicate that it is hacked up.

    On the back of the light switch is a circuit breaker in case there is a dead short in the lights.

    Your ign wire may run through the breaker or just use the breaker terminal as a junction point.

    kamel
     
  6. Jul 25, 2005
    66cj5

    66cj5 Jeep with no name

    NorthWest Indiana
    Joined:
    Sep 10, 2003
    Messages:
    2,084
    found the short. hot lead from fan switch touched the tub. might get the rebuilt transfer case installed by attica.
     