Discussion in 'Intermediate CJ-5/6/7/8' started by H Tate, Sep 14, 2022.

  1. Sep 14, 2022
    H Tate

    H Tate Member

    Central Texas
    Joined:
    Aug 28, 2022
    Messages:
    147
    At least it was in front of my house so pushing it home wasn't too bad. Who ever owned it before me duct taped the wire and put it in the loom which makes me think this happened before. Time for a total rewire. 20220914_154917.jpg 20220914_154909.jpg
     
  2. Sep 14, 2022
    58 willys

    58 willys Sponsor

    Millsboro, Delaware
    Joined:
    Jul 2, 2010
    Messages:
    948
    Holy Smokes
     
  3. Sep 14, 2022
    Ohiowrangler

    Ohiowrangler Member 2024 Sponsor 2023 Sponsor 2022 Sponsor

    Newark, Ohio
    Joined:
    May 29, 2019
    Messages:
    271
    better lucky than good, glad all is well. Ron
     
  4. Sep 15, 2022
    Jeepenstein

    Jeepenstein Me like Jeep.. 2024 Sponsor

    North Central FL
    Joined:
    Jun 15, 2003
    Messages:
    2,156
    The magic smoke..
     
    Joe Dokes likes this.
  5. Sep 15, 2022
    Bondo

    Bondo Master General Re-Engineer,...

    Greenfield Me.
    Joined:
    Dec 17, 2021
    Messages:
    89
    Ayuh,..... That, seems to be the most excitin' part of buyin' an ole Jeep,.....

    My most common question is,.... WTF was he thinkin',..??..??

    My current project is strippin' out all the wires that go nowhere, other than into a plastic loom, 'n rewirin' the dash,.....
    Got the new gauges in, 'n hooked up,.... removed the fusebox, from on Top of the brake peddle assembly, 'n gonna mount it where it can be seen, 'n able to change the fuses,.....
     
    Joe Dokes likes this.
  6. Sep 15, 2022
    Howard Eisenhauer

    Howard Eisenhauer Administrator Staff Member

    Tantallon, Nova...
    Joined:
    Nov 22, 2003
    Messages:
    8,118
    So why has it been getting that hot?
     
  7. Sep 15, 2022
    John Strenk

    John Strenk Member

    Shalersville, Ohio
    Joined:
    Nov 28, 2006
    Messages:
    112
    It might be because there looks like there is a lot of corrosion on the wire reducing the current carrying capacity of that wire. As the copper turns into cuprous oxide, it will not conduct electricity anymore.
    So if the current draw remains the same, then it will start to over heat. Same as using too small of gauge wire.

    Cant tell is that is the fusible link or not.
     
  8. Sep 15, 2022
    H Tate

    H Tate Member

    Central Texas
    Joined:
    Aug 28, 2022
    Messages:
    147
    All new wiring going in this weekend.
     